- Cat. No. 2110-0



Size: 480 mL
- Colorimetric Endpoint Method Using Bromcresol Green

- Reaction at Ambient Temperature for 30-sec or 5-minutes

- Absorbance maxima @ 630 nm

- Kit includes: Albumin BCG Rgt & Albumin Std

Alkaline Phosphatase
- Cat. No. 2115-0



Size: 120 Test
- Colorimetric Endpoint Method Using TPMP Substrate

- Reaction at 37ºC for 10-minutes

- Absorbance maxima @ 590 nm

- Kit includes: Substrate, Diluent, Standard, Activator

Bilirubin, Total & Direct
- Cat. No. 2130-0



Size: 80 & 80 Tests
- Colorimetric Endpoint Method Using Diazotization

- Ambient Reaction: 1-minute Direct & 5-minutes Total

- Absorbance maxima @ 540 nm

- Kit includes: Bilirubin Rgt., Sulfanilic Acid, Sodium Nitrite & Calibrator

Bilirubin, Total
- Cat. No. 2135-0



Size: 315 mL
- Colorimetric Endpoint Method Using Diazotization

- Ambient Reaction: 5-minutes Total

- Absorbance maxima @ 540 nm

- Kit includes: Bilirubin Rgt., Sulfanilic Acid, Sodium Nitrite & Calibrator

Calcium (CPC)
- Cat. No. 2140-0



Size: 2 x 240 mL
- Colorimetric Endpoint Method Using Cresolphthalein Complexone

- Cyanide-Free Reagents

- Ambient Reaction: 1-minute

- Absorbance maxima @ 575 nm

- Kit includes: Color Reagent, Base Reagent & Standard

Cholesterol, Total
- Cat. No. 2145-L



Size: 960 mL
- Enzymatic Colorimetric Endpoint Method (Trinder)

- Phenol-Free, All Liquid Reagents
- 37 C Reaction for 10-minutes

- Stability of Single Working Reagent: 6 months

- Absorbance maxima: 510 nm

- Kit includes: Liquid Buffer, Liquid Enzyme & Standard

Cholesterol, HDL
- Cat. No. 2150-P



Size: 50 mL
- Simple Modified PEG Separation Method

- Exceptional Precision with Enzymatic Cholesterol

- Kit includes: PEG Precipitating Reagent & Standard

Cholesterol, LDL
- Cat. No. 2214-0



Size: 100 x 0.4 mL
- Simple Separation Method

- Exceptional Precision with Enzymatic Cholesterol

- Kit includes: Precipitating Reagent, Standard and Controls

Creatine Kinase
- Cat. No. 2155-0



Size: 120 Test
- Colorimetric Endpoint Method

- 37 C Reaction: 10-minutes

- NAC-Activated

- Absorbance maxima: 500 nm

- Kit includes: Buffer, Enzyme, Color, & Calibrator

Creatinine
- Cat. No. 2167-0



Size: 720 mL
- Colorimetric Endpoint Method

- Ambient Reaction: 15-minutes

- Absorbance maxima: 520 nm

- Kit includes: Buffer, Picric Acid Reagent,

Clearing Reagent, Standard
Creatinine-Rate
- Cat. No. 2170-0



Size: 500 mL
- Colorimetric Rate Method

- 45-second reaction at 25, 30, or 37 C

- Kit includes: Base, Picric Acid & Two Levels of Standard

Fatty Acids (Non-Esterified or Free) (NEFA)
- Cat. No. 2173-0



Size: 50 Test
- Colorimetric Enzymatic Endpoint Method

- 20-minute reaction at 37°C

- Absorbance maxima: 550 nm

- Sample requirement: 50 ul (serum)

- Linear to 2000 umol/L (2.0 mEq/L)

- Standard included

Gamma Glutamyl Transpeptidase-Endpoint (GGTP-EP)
- Cat. No. 2175-0



Size: 80 Test
- Colorimetric Endpoint or Rate Method

- Endpoint Method: 10-minutes at 37 C

- Absorbance maxima: 405 nm

- Kit includes: Buffer, Substrate, Diluent, Quenching Reagent, Standard

Glucose (Trinder)
- Cat. No. 2185-L



Size: 960 mL
- Enzymatic Colorimetric Endpoint Method (Trinder)

- Phenol-Free, All Liquid Reagents

- 37 C Reaction: 10-minutes

- Stability of Single Working Reagent: > 30 days

- Absorbance maxima: 510 nm

- Kit includes: Liquid Buffer, Liquid Enzyme & Standard

Glycohemoglobin
- No Chromatographic Columns Required

- 10-minute separation/reaction time

- Requires only 100 ul Whole Blood sample

- Absorbance maxima: 415 nm

- Kit includes: Ionex Buffered Resin, Separators, Lysing Reagent, Calibrator and Controls

Glycohemoglobin Calibrator and Control Set
- Cat. No. 2193-C



Size: 3 x 1 mL
Glycohemoglobin Linearity Set
- Cat. No. 2193-L



Size: 4 x 0.1 mL
Iron/Iron Binding Capacity
- Cat. No. 2200-0



Size: 2 x 250 mL
- Colorimetric Endpoint Method

- 10-minute Reaction Time for Iron and UIBC

- Absorbance maxima: 565 nm

- Kit includes: Iron & UIBC Buffer, Color Reagent, Standard

Magnesium (Calmagite)
- Cat. No. 2220-0



Size: 300 mL
- Colorimetric Endpoint Method Using Calmagite

- Cyanide-Free Reagents

- Ambient Reaction: 1-minute

- Absorbance maxima @ 530 nm

- Kit includes: Color Reagent, Buffer Reagent & Standard

Potassium
- Cat. No. 2238-0



Size: 60 Test
- Turbidimetric Method with Absorbance Measured @ 420 nm

- 100 ul Sample Size and 10 mEq/L Linearity

- Kit includes: ProCip Reagent, Boron Reagent, Base Reagent and Standard

Protein, Total
- Cat. No. 2240-0



Size: 160 Test
- Colorimetric Method with Absorbance Measured @ 540 nm

- 10-minute Reaction Time

- Kit includes: Biuret Reagent and Total Protein Standard

Sickle Cell
- Cat. No. 2243-0



Size: 50 Test
- Qualitative Phosphate-Dithionite Solubility Test for Sickle Cell Trait or Sickle Cell Anemia

- 5-minute Reaction Time @ Ambient Temperature

- Includes Hemoglobin S Confirmation Step using Urea

- Kit includes: Buffer, Lysing Reagent, Urea Reagent

Sickle Cell Control
- Cat. No. 2244-0

Size: 4 x 0.5 mL (2 positive, 2 negative)
- Cat. No. 2244-1

Size: (2 x 2.5 mL Positive; 2 x 2.5 mL Negative)
SGOT/AST-Colorimetric
- Cat. No. 2250-0



Size: 200 Test
- Colorimetric Method measured @ 530 nm

- 20-minute Total Incubation Time @ 37°C.
- Kit includes: Substrate, Color Reagent, Calibrator

SGPT/ALT-Colorimetric
- Cat. No. 2260-0



Size: 120 Test
- Colorimetric Method measured @ 505 nm

- Total Reaction Time: 25-minute @ 37°C.

- Kit includes: Substrate, Color Reagent, Color Developer, Calibrator

Sodium
- Cat. No. 2266-0



Size: 60 Test
- Turbidimetric Method measured at 550 nm

- 10-minute test time requiring only 20 ul sample

- Linear to 225 mEq/L

- Kit includes: ProCip Reagent, Acid Reagent, Color Reagent, and Standard

Triglyceride (INT)
- Cat. No. 2275-0



Size: 140 Test
- Enzymatic Colorimetric Method measured at 500 nm

- 10-minute reaction at 37°C

- Linearity to 700 mg/dl

- Kit includes: Buffer, Enzyme, Standard

Triglyceride (GPO)
- Cat. No. 2285-0




Size: 300 Test
- Enzymatic Trinder Endpoint Method

- 10-minute reaction at 37°C measured at 505 nm

- Linearity to 1000 mg/dl

- Kit includes: Buffer, Enzyme and Standard

BUN (Berthelot)
- Cat. No. 2290-L



Size: 250 Test
- Enzymatic Colorimetric Berthelot Method

- Phenol-Free Reagents

- 10-minute Incubation at 37°C

- Linearity to 45 mg/dl

- Kit includes: Enzyme, Color Reagent, Base Reagent,
Uric Acid (Trinder)
- Cat. No. 2305-0



Size: 200 Test
- Enzymatic Colorimetric Trinder Method

- 10-minute reaction at 37°C

- Absorbance measured at 515 nm

- Linearity to 30 mg/dl

- Kit includes: Buffer, Enzyme and Standard

Sterling Spectro-Monitor
- Cat. No. 2325-0



Size: 1 kit
- For UV and Visible Calibration of Photometers

- Kit includes: 3 Chromate Solutions for UV and 3 Cobalt Solutions for Visible